GLOBAL

     Search

Click on the program link below and go
to the program's
You are interested in...

HOME  >  PRODUCTS  >  Perkins Engine Series(open type)

Perkins Engine Series(open type)

Product Description
+ Open-shelf Generator---- product description
+ Efficient dynamics and long-lasting use
+ Convenient service and installation
+ LCD/Normal Standard Data Displays
+ DeepSea, SmartGen, etc intelligent controller
+Special design for harsh environment

Model Prime/Standby Power Engine Model Cylinder No. Displacement (L) Oil Capacity (L) Coolant Capacity (L) Dimension (mm) Weight   (kg)
KVA KW Perkins L W H
KP08P 9/10 7.2/8 403D-11G 3 1.1 4.9 5.2 1320 552 1258 400
KP10P 13.5/15 10.8/12 403D-15G 3 1.1 6 6 1320 552 1258 450
KP16P 20/22 16/17.7 404D-22G 4 2.2 10.6 7 1320 552 1258 470
KP24P 30/33 24/26.4 1103A-33G 3 3.3 7.9 10.2 1470 620 1280 520
KP30P 37/41 30/33 1103A-33TG1 3 3.3 7.9 10.2 1470 620 1280 580
KP36P 45/50 36/40 1103A-33TG1 3 3.3 7.9 10.2 1470 620 1280 620
KP48P 60/65 48/52 1103A-33TG2 3 3.3 7.9 10.2 1470 620 1280 650
KP52P 65/73 52/58 1104A-44TG1 4 4.4 8 13 1590 710 1300 780
KP64P 80/88 64/70 1104A-44TG2 4 4.4 8 13 1590 710 1300 850
KP72P 90/100 72/80 1104C-44TAG2 4 4.4 10 13 1800 790 1350 980
KP80P 100/110 80/88 1104C-44TAG2 4 4.4 10 13 1800 790 1350 1050
KP100P 125/140 100/112 1106A-70TAG1 6 7.01 16.5 21 2300 820 1380 1200
KP120P 150/165 120/132 1106A-70TAG2 6 7.01 16.5 21 2450 880 1500 1350
KP140P 175/200 144/160 1106A-70TAG3 6 7.01 16.5 21 2600 910 1680 1550
KP160P 200/220 160/176 1106A-70TAG4 6 7.01 16.5 21 2980 980 1840 2050
KP180P 225/245 180/196 1306C-E87TAG4 6 8.7 26.4 37.2 2980 980 1840 2150
KP200P 250/275 200/220 1306C-E87TAG6 6 8.7 26.4 37.2 2980 980 1840 2550
KP280P 350/400 280/320 2206C-E13TAG2 6 13 68 47 3100 1050 1980 2950
KP320P 400/450 320/360 2206C-E13TAG3 6 13 68 47 3100 1050 1980 3000
KP360P 450/500 360/400 2506C-E15TAG1 6 15 62 58 3300 1150 2195 3300
KP400P 500/550 400/440 2506C-E15TAG2 6 15 62 58 3300 1150 2195 3950
KP480P 600/660 480/528 2806A-E18TAG1A 6 18 68 50 3500 1150 2195 4550
KP520P 650/712 520/570 2806A-E18TAG2 6 18 68 50 3500 1150 2195 4700
KP580P 725/800 580/638 4006-23TAG2A 6 23 113.4 105 3900 1470 2195 5000
KP640P 800/900 640/720 4006-23TAG3A 6 23 113.4 105 4400 1470 2195 5250
KP728P 910/1000 728/800 4008TAG1A 8 31 166 143 4800 2050 2445 7400
KP800P 1000/1100 800/880 4008TAG2A 8 31 166 149 4800 2050 2445 7650
KP1000P 1250/1375 1000/1100 4012-46TWG2A 12 46 177.6 185 5000 2300 2875 8150
KP1090P 1363/1500 1090/1200 4012-46TWG3A 12 46 177.6 190 5000 2300 2875 8950
KP1200P 1500/1650 1200/1320 4012-46TAG2A 12 46 177.6 235 5000 2300 2875 9150
KP1360P 1700/1875 1360/1500 4012-46TAG3A 12 46 177.6 235 5000 2300 2875 11200
KP1400P  1750/1925 1400/1540 4016TAG 16 61 237.2 255 5400 2650 2650 13250
KP1460P 1825/2000 1460/1600 4016TAG1A 16 61 237.2 260 5400 2650 2650 15500
KP1640P 2050/2250 1640/1800 4016TAG2A 16 61 237.2 316 5400 2650 2650 18000

Remarks: 
 ● Above model, technical specifications are based on 50HZ, for 60HZ, please contact supplier to provide separately.
 ● Standards: ISO8525(GB/T2820-97), ISO3046, GB755, BS5000, VDE0530, IEC34-1, NEMA MG1-32, CSA22.2, AS1359
 ● Recommended alternator brand: Stamford, Leroy Somer, Marthon etc.
 ● We reserve the right to make the change in model, technical specifications without prior notice. 


Diesel Engine
With Perkins series engine as the power source. Applicable to 7.2-1800KW generator set.
Optional mechanical or electrical governor, with excellent speed response characteristics
Optional engine speed (1500rpm, 1800rpm, 3000rpm), which reflects the strong power and economic efficiency of the set.
Optimum power output characteristics
Engines are available with three different air intaking methods– natural aspiration, charged and charge inter-cooling.
Synchronous Alternator
Alternator
•Four-pole rotating magnetic field, self-ventilating radiation system formed by rotor blade 
•2/3 pitch winding, effectively eliminating the sub or ultra harmonic and increasing the paralleling capability
•excellent short circuit withstand ability
•Brushless rotating exciter with rotor/stator exciting system, three-phase rectified bridge
•Insulation grade: H
•Single-ended support mounting way minimizes the vibration of operating generator
•Standard wiring with three-phase four-wire and star connection output
•Auxiliary AVR ensures the steady state voltage deviation compliant with ISO 8528G3
•High quality electromagnetic winding coil
•Integrated design combining the AC output main winding and exciting system
•Rotor damper windings improve the output wave of generator and minimum the wave distortion
•Minimum the generator reactance characteristics
•Maximize the efficiency of electromagnetic induction power generation
Complete Auxiliary Equipment System
•The generator set is installed with internal vibration damper, controller, starting system and auto-monitoring system, to form an integrated power station generator set.
•The internal cushion is made of special rubber
•No need for additional cushion to connect and fix the base to ground.
Output
Apply connection pole for generator set full power output
ATS configuration option
ATS dual-power auto-switch system introduces the specialized dual-power switch with self-locker.
Control System
Controller is a control system independently researched and developed. It applies the microprocessor technology, with the function of measurement, control and protection, and accurately measures various parameters. Cooperating with its self-developed ATS module, it can realize the manual/auto switch control between the generator set and utility power.
Engine Protection 
Over/Under speed alarm/shut down
Starting fail shut down
Low oil pressure alarm/shutdown
High coolant temperature alarm/shutdown
Low fuel level alarm/shut.
Charging fault alarm
High/low battery voltage alarm
Internal Control
• Manual/ automatic operation mode option
• Wireless remote start
• Electric door lock start
• Emergency shut down
• Engine speed testing 
• Engine start
• Barring
Alternator
• Over/Under voltage shut down      
• Over current alarm/shut down
• Under frequency shut down          
• Over frequency shut down
Standard protection
During the operation, the control system may display the fault on panel by lighting up the relative LED and revealing the fault code and explanation on LCD, with the internal buzzer sounding for alarm.
LCD Data Displays
• Generator set parameters          
• Engine speed 
• Output frequency      
• Output phase voltage 
• Output line voltage       
• Oil pressure
• Coolant temperature        
• Oil temperature (optional)
• Fuel level             
• Clock
• Battery voltage              
• Battery charging current
• Output current            
• Active power
• Reactive power         
• Power factor
• Continuous running time    
• Output power 
• Grid frequency               
• Grid three-phase phase voltage
• Grid network three-phase line voltage
• Fault history

Copyright©2013 SHANGHAI GLOBAL INTERNATIONAL All Rights Reserved