GLOBAL

     Search

Click on the program link below and go
to the program's
You are interested in...

HOME  >  PRODUCTS  >  Duetz Engine Series(open type)

Duetz Engine Series(open type)

Product Description
+ Open-shelf Generator---- product description
+ Efficient dynamics and long-lasting use
+ Convenient service and installation
+ LCD/Normal Standard Data Displays
+ DeepSea, SmartGen, etc intelligent controller
+Special design for harsh environment

Model Power Engine Model Cylinder No. Bore*Stroke (mm) Fuel Consumption (g/kw.h) Dimension (mm) Weight (kg)
KVA KW
Water-cooled Series
KP20D 25 20 D226B-3D 3 105*120 208 1800*800*1250 800
KP24D 30 24 D226B-3D 3 105*120 208 1800*800*1250 820
KP30D 37.5 30 TD226B-3D 3 105*120 208 1800*800*1250 870
KP40D 50 40 TD226B-3D 3 105*120 208 1800*800*1250 930
KP48D 60 48 TD226B-4D 4 105*120 208 2000*800*1300 1000
KP70D 87.5 70 TD226B-6D 4 105*120 208 2400*900*1400 1150
KP80D 100 80 TD226B-6D 6 105*120 208 2400*900*1400 1250
KP100D 125 100 TBD226B-6D 6 105*120 208 2400*900*1400 1330
KP112D 140 112 TBD226B-6D 6 105*120 208 2400*900*1400 1350
KP120D 150 120 TBD226B-6D5 6 105*120 208 2400*900*1500 1450
KP200D 250 200 BF6M1015 6 132*145 205 2450*1050*1800 1900
KP280D 350 280 BF6M1015C 6 132*145 205 3050*1300*1800 2300
KP300D 375 300 BF6M1015KP 6 132*145 205 3050*1300*1800 2550
KP360D 400 360 BF8M1015C 8 132*145 205 3200*1500*1800 2850
KP400D 500 400 BF8M1015KP 8 132*145 205 3200*1500*1800 3200
Remarks: 
 ● Above model, technical specifications are based on 50HZ, for 60HZ, please contact supplier to provide separately.
 ● Standards: ISO8525(GB/T2820-97), ISO3046, GB755, BS5000, VDE0530, IEC34-1, NEMA MG1-32, CSA22.2, AS1359
 ● Recommended alternator brand: Stamford, Leroy Somer, Marthon etc.
 ● We reserve the right to make the change in model, technical specifications without prior notice.


Diesel Engine
With Duetz  series engine as the power source. Applicable to 12-400KW generator set.
Optional mechanical or electrical governor, with excellent speed response characteristics
Optional engine speed (1500rpm, 1800rpm, 3000rpm), which reflects the strong power and economic efficiency of the set.
Optimum power output characteristics
Engines are available with three different air intaking methods– natural aspiration, charged and charge inter-cooling.
Synchronous Alternator
Alternator
•Four-pole rotating magnetic field, self-ventilating radiation system formed by rotor blade 
•2/3 pitch winding, effectively eliminating the sub or ultra harmonic and increasing the paralleling capability
•excellent short circuit withstand ability
•Brushless rotating exciter with rotor/stator exciting system, three-phase rectified bridge
•Insulation grade: H
•Single-ended support mounting way minimizes the vibration of operating generator
•Standard wiring with three-phase four-wire and star connection output
•Auxiliary AVR ensures the steady state voltage deviation compliant with ISO 8528G3
•High quality electromagnetic winding coil
•Integrated design combining the AC output main winding and exciting system
•Rotor damper windings improve the output wave of generator and minimum the wave distortion
•Minimum the generator reactance characteristics
•Maximize the efficiency of electromagnetic induction power generation
Complete Auxiliary Equipment System
•The generator set is installed with internal vibration damper, controller, starting system and auto-monitoring system, to form an integrated power station generator set.
•The internal cushion is made of special rubber
•No need for additional cushion to connect and fix the base to ground.
Output
Apply connection pole for generator set full power output
ATS configuration option
ATS dual-power auto-switch system introduces the specialized dual-power switch with self-locker.
Control System
Controller is a control system independently researched and developed. It applies the microprocessor technology, with the function of measurement, control and protection, and accurately measures various parameters. Cooperating with its self-developed ATS module, it can realize the manual/auto switch control between the generator set and utility power.
Engine Protection 
Over/Under speed alarm/shut down
Starting fail shut down
Low oil pressure alarm/shutdown
High coolant temperature alarm/shutdown
Low fuel level alarm/shut.
Charging fault alarm
High/low battery voltage alarm
Internal Control
• Manual/ automatic operation mode option
• Wireless remote start
• Electric door lock start
• Emergency shut down
• Engine speed testing 
• Engine start
• Barring
Alternator
• Over/Under voltage shut down      
• Over current alarm/shut down
• Under frequency shut down          
• Over frequency shut down
Standard protection
During the operation, the control system may display the fault on panel by lighting up the relative LED and revealing the fault code and explanation on LCD, with the internal buzzer sounding for alarm.
LCD Data Displays
• Generator set parameters          
• Engine speed 
• Output frequency      
• Output phase voltage 
• Output line voltage       
• Oil pressure
• Coolant temperature        
• Oil temperature (optional)
• Fuel level             
• Clock
• Battery voltage              
• Battery charging current
• Output current            
• Active power
• Reactive power         
• Power factor
• Continuous running time    
• Output power 
• Grid frequency               
• Grid three-phase phase voltage
• Grid network three-phase line voltage
• Fault history